Please activate JavaScript!
Please install Adobe Flash Player, click here for download

elneos five EN

38 | elneos® five Telecontrol, interfaces and software All device functions can be tele-controlled by SCPI standard (Standard Commands for Programmable Instruments). There are two basic tele-control modes: Telecontrol mode1 In this mode the device responds exclusively to com- mands which have been sent through the interface. The device operation on the front panel is deactivated. Telecontrol mode2 with pre-specified limit In this mode the operation of the device at the front panel is admitted. Limit values can be transferred by means of the interface. The transferred values can- not be exceeded at the device. This protects sensitive circuits and avoids damage to test items. The up-to-date values are continuously read and trans- ferred through the interface. The erfi software highlink Power and the LabVIEW device driver visualize the arriving data. This allows the surveillance of all devices at any place and time. Interfaces (standard) • USB 2.0 • Ethernet Other interfaces on request Note: The interface rests always on an earthed potential. The internal telecontrol interfaces of the e-bus do not rest on the potential of the function module. This guarantees a high functional safety. Software elneos five can be telecontrolled by means of the de- vice control software highlink Power elneos, the room control software highlink Power, the LabVIEW device driver or the modern web server. Due to the device language SCPI being used, the application as OEM product is easily possible. Data logger/ Measured value storage elneos five has an internal device storage for up to 2000 measured values. An additionally integrated time stamp ensures a professional measured value acquisition as well as a time-synchronised acquisition of 4 different measured values! Graphical representation of measured values The stored measured values as well as all up-to-date measured values can be fast visualized in X-Ycharts on the large 7"multitouch display. With the modern contact control, charts can be enlarged. Calibration Also with respect to calibration elneos five sets new standards. Internal calibrating routines allow the easy calibration of the devices. Mechanical interventions are precluded and there is no need any more to open the devices for calibration. The calibrating parameters can be transferred to the device through an interface. The new circuit technology allows the fully automatic calibration. The tolerances due to construction parts are neutralized by integrated automatic calibrating rou- tines and respective hardware provisions. The result is a considerable cost reduction thanks to a fast and easy calibration either at customer’s site or in the factory. In addition, we offer you an all-over calibrating service.The scope of supply includes a cost-free factory calibrating certificate.

Seitenübersicht